BS EN 3-11 Explained: Frequently Asked Questions About Lithium-Ion Fire Extinguishers

BS EN 3-11 Explained: Frequently Asked Questions About Lithium-Ion Fire Extinguishers

Blog post July 29-2-4

Lithium-ion batteries now power everything from smartphones and laptops to power tools, e-bikes and portable medical equipment. 

Although these batteries are generally safe when correctly manufactured, used and charged, damage, overheating, manufacturing defects or incorrect charging can lead to thermal runaway. This can produce intense heat, flames, hazardous gases and the potential for fire to spread between cells.  

As lithium-ion battery use has increased, so has the need for clearer and more consistent ways to assess the portable extinguishers intended for these incidents. 

This is where BS EN 3-11 comes in. 

The proposed standard is intended to add lithium-ion-specific testing and marking requirements to the existing EN 3 framework for portable fire extinguishers. However, its scope, status and limitations must be clearly understood.  

Here, Firechief® answers some of the most frequently asked questions. 

Sources: BSI lithium-ion battery safety webinar | London Fire Brigade battery-fire guidance


What is BS EN 3-11?

BS EN 3-11 is the proposed new part of the EN 3 series covering portable fire extinguishers. 

Its full title is: 

Portable fire extinguishers. Part 11: Additional requirements to EN 3-7 for the test method and marking of extinguishers suitable to be used on small rechargeable lithium-ion battery fires. 

Rather than replacing the existing portable extinguisher standard, it is being developed to introduce additional requirements for extinguishers intended for use on small lithium-ion battery fires. These requirements are expected to address how performance is tested and how demonstrated suitability is communicated through product marking.  

It is worth noting that the draft EN 3-11 protocol is largely based on the Dutch NTA 8133 guideline, which was developed to evaluate the effectiveness of extinguishing agents against lithium-ion battery fires under controlled and realistic test conditions. 

Sources: BSI standards-development project | BSI Knowledge: 25/30507060 DC


Has BS EN 3-11 been published?

Not as a completed British Standard at the time of writing. 

A draft for development, identified as 25/30507060 DC, was published by BSI for consultation on 20 February 2025. BSI’s standards-development record shows that the draft and public-comment stages have been completed and that the project has progressed through comment resolution. It currently lists publication activity beginning on 18 September 2026.  

Until the final standard is formally published, its wording, requirements and timetable may still change. 

This distinction is important. The consultation document may be described as draft BS EN 3-11 or prEN 3-11, but it should not be presented as though the final standard is already in force. 

Sources: BSI Knowledge: draft publication record | BSI FSH/2 committee project status


Why is a separate standard needed?

The current BS EN 3-7 establishes characteristics, performance requirements and test methods for portable fire extinguishers. It provides the principal framework used for conventional extinguisher construction and performance, but it was not developed specifically around the behaviour of lithium-ion battery fires.  

Lithium-ion battery incidents present different challenges. 

When a battery cell enters thermal runaway, heat can build faster than it can be dissipated. This may cause off-gassing, fire, rupture or an explosion, while the heat released by one cell can contribute to failure in neighbouring cells. Even after visible flames have been controlled, continued heat generation and re-ignition may remain concerns.  

A lithium-ion-specific test method would therefore help provide a more consistent way to assess whether an extinguisher meets the performance requirements under defined battery-fire test conditions. 

Sources: BSI Knowledge: BS EN 3-7 | BSI lithium-ion fire-suppression whitepaper


Does BS EN 3-11 replace EN 3-7?

No. 

BS EN 3-11 is intended to provide additional requirements to EN 3-7, rather than create a completely separate portable extinguisher framework. 

A portable extinguisher would still need to meet the requirements of BSEN3-7, which provide the core framework. Once BS EN 3-7 requirements have been satisfied, the final scope of BS EN 3-11 applies.  

A simple way to understand the relationship is: 

  • EN 3-7: provides the core framework for general characteristics, performance requirements and test methods for portable extinguishers. 
  • EN 3-11: additional testing and marking for extinguishers intended for defined small lithium-ion battery fire applications. 

What types of battery fires will the standard cover? 

The BSI project title specifically refers to small rechargeable lithium-ion battery fires.  

This is an important limitation. 

BS EN 3-11 should not be interpreted as providing blanket approval for every incident involving lithium-ion technology. Battery risks vary considerably depending on factors such as: 

  • Battery energy and physical size 
  • Cell chemistry and configuration 
  • Whether the battery is accessible 
  • The number of cells involved 
  • The surrounding combustible materials 
  • Whether the battery is part of a vehicle or fixed energy-storage system 
  • The stage and severity of thermal runaway 

A product performing successfully against a defined small-battery test does not automatically demonstrate that it can manage a significantly larger battery system. 

The final published scope and the product’s documented test rating should always be checked. 

Sources: BSI Knowledge: BS EN 3-7 | FprEN 3-11 scope summary


What types of battery fires will the standard cover?

The BSI project title specifically refers to small rechargeable lithium-ion battery fires. 

This is an important limitation.

BS EN 3-11 should not be interpreted as providing blanket approval for every incident involving lithium-ion technology. Battery risks vary considerably depending on factors such as:

  • Battery energy and physical size
  • Cell chemistry and configuration
  • Whether the battery is accessible
  • The number of cells involved
  • The surrounding combustible materials
  • Whether the battery is part of a vehicle or fixed energy-storage system
  • The stage and severity of thermal runaway

A product performing successfully against a defined small-battery test does not automatically demonstrate that it can manage a significantly larger battery system.

The final published scope and the product’s documented test rating should always be checked.

Sources: FprEN 3-11 scope summary | BSI Knowledge: consultation draft


Will BS EN 3-11 create a new lithium-ion fire class?

No. BS EN 3-11 is an extinguisher performance, testing and marking standard. 

It should not be confused with a fire-classification document. ISO published the revised ISO 3941:2026 "Classification of Fires" in January 2026, introducing Class L as a dedicated classification for lithium-ion cell and battery fires. 

The purpose of BS EN 3-11 is to establish additional requirements through which an EN 3-7 extinguisher can demonstrate suitability for the lithium-ion battery scenarios included within the standard’s defined scope.  

In other words, it is concerned with how an extinguisher is tested and marked, not simply withnaming or classifying the type of fire. Having said that, the draft standard does specify a fire class pictogram to be positioned alongside the current standardised fire classifications (A, B, C, as relevant), showing a Li battery fire themed design, which heralds a new type of fire classification for European portable extinguishers. 

Sources: BSI standards-development project | BSI Knowledge: consultation draft


Will every lithium-ion extinguisher automatically comply?

No. 

Products will not automatically comply merely because they: 

  • Contain an agent commonly associated with battery fires 
  • Are marketed as lithium-ion extinguishers 
  • Have previously been tested against a different protocol 
  • Belong to the same product family as another tested extinguisher 
  • Have an existing EN 3 rating for conventional fire classes 

Conformity will depend on the exact requirements in the final standard and the evidence available for the specific extinguisher model. 

BSI has previously emphasised that product-performance validation should relate to defined and repeatable test requirements. Its interim compliance-certification process also documents the battery configuration, chemistry and capacity used during witness testing and verifies the particular productplaced under test.  

This reinforces an essential principle: performance claims must be product-specific and supported by appropriate evidence. 

Sources: BSI lithium-ion fire-suppression whitepaper | BSI fire-suppression testing and certification


What will the marking on an extinguisher mean?

The proposed standard is expected to establish a consistent method of marking extinguishers that have The proposed standard is expected to establish a consistent method of marking extinguishers that have successfully met its requirements, adding a fire class pictogram with ‘Li’ and a battery icon. 

This should make it easier for fire-safety professionals, responsible persons and purchasers to understand that a product has been tested under a defined lithium-ion battery fire protocol. 

However, a mark should never be read in isolation. 

Users will still need to check: 

  • The exact extinguisher model tested 
  • The level or size of risk represented by its test rating 
  • Any limitations stated by the manufacturer 
  • The battery applications for which it is intended 
  • Safe operating instructions 
  • Required separation distances and personal protection 
  • Procedures for evacuation, ventilation and post-incident monitoring 

A marking demonstrates performance under specified conditions. It does not remove the need for a suitable and sufficient fire-risk assessment. 

Sources: BSI Knowledge: BS EN 3-11 draft title and scope | BSI fire-suppression testing and certification


Does passing a test mean an extinguisher can stop thermal runaway?

Not necessarily. Indeed the draft standard recognises the limitations of most extinguishing mediums in stopping thermal runaway within a single battery cell. However, the test does focus on stopping the propagation of fire from cell to cell within a simulated battery pack. 

The practical objectives of intervention may include: 

  • Cooling the battery 
  • Controlling visible flames 
  • Reducing fire propagation 
  • Limiting heat transfer to neighbouring cells or materials 
  • Creating more time for evacuation and emergency response 

The effectiveness of any intervention will depend on the battery, the stage of failure, the extinguisher’s capacity and the circumstances surrounding the incident. 

BSI describes thermal runaway as heat building within a battery faster than it can be dissipated, potentially leading to off-gassing or explosion and cascading failure between cells.  

Sources: BSI lithium-ion battery safety webinar | BSI lithium-ion fire-suppression whitepaper


Does BS EN 3-11 remove the need for a lithium-ion battery risk assessment?

No. 

Selecting an extinguisher is only one part of lithium-ion battery fire safety. 

A risk assessment should also consider: 

  • Which batteries are present 
  • Their capacity, chemistry and condition 
  • Where and how they are charged 
  • Whether charging takes place unattended 
  • The use of compatible, manufacturer-approved chargers 
  • Storage of damaged, swollen or recalled batteries 
  • Escape routes and compartmentation 
  • Detection and alarm arrangements 
  • Battery containment and fire-resistant storage 
  • Staff training and emergency procedures 
  • Arrangements for calling the fire and rescue service 
  • Post-incident isolation, monitoring and disposal 

Equipment selection should be based on the actual risk rather than on a general claim that a product is suitable for “lithium batteries”. 

Sources: GOV.UK workplace fire-risk assessment guidance | Essex Fire lithium-ion business guidance


Can ordinary extinguishers be used on lithium-ion battery fires?

A conventional extinguisher may control surrounding materials that have caught fire, but that does not mean it has demonstrated the cooling or propagation-control performance required for a lithium-ion battery incident. 

Lithium-ion batteries should also not be confused with lithium-metal fires. They involve different hazards, and equipment intended for one should not automatically be assumed suitable for the other. 

Where lithium-ion batteries form part of the risk, seek competent advice and choose equipment supported by relevant, application-specific testing. 

Sources: BSI lithium-ion fire-suppression whitepaper | BSI fire-suppression testing and certification


What does BS EN 3-11 mean for Firechief® customers?

The development of BS EN 3-11 is a positive step towards greater consistency and transparency across the fire-safety industry. 

It should help customers compare products using: 

  • A defined test method 
  • Clearer performance evidence 
  • More consistent markings 
  • Better-understood limitations 
  • A common European framework 

Firechief® already provides a dedicated range of Lith-Ex extinguishers designed for lithium-ion battery fire risks, with portable models intended for applications involving devices such as phones, laptops, tools and e-scooters. These extinguishers are tested and certified to the Dutch standard, NTA 8133 on which the BS EN3-11 has been largely based. 

Firechief® is committed to achieving the BSI Kitemark to the new standard as soon as this is possible, and will continue to monitor the standard’s development and communicate verified, product-specific information as the testing and certification landscape progresses. 

Sources: Firechief® Lith-Ex extinguisher range | BSI standards-development project


What should customers do now?

Organisations should not wait for publication of a new standard before reviewing their lithium-ion battery risks. 

Start by identifying where batteries are being: 

  • Used 
  • Charged 
  • Stored 
  • Transported 
  • Collected for disposal 

Then assess the potential battery size and severity of an incident, the people who could be affectedand the measures needed to prevent, detect, contain and respond to a fire. 

When evaluating an extinguisher, ask for clear evidence showing: 

  1. Which exact model was tested 
  2. Which test method was used 
  3. The battery configuration and capacity involved 
  4. The limits of the product’s intended application 
  5. Whether additional containment, cooling or evacuation measures are required 

A logo, pictogram or general marketing statement should never replace proper technical evidence. 

Sources: GOV.UK workplace fire-risk assessment guidance | Essex Fire lithium-ion business guidance


Preparing for a Clearer Testing Framework

BS EN 3-11 represents an important development for portable lithium-ion battery fire extinguishers. 

By introducing a standardised test method and clearer marking requirements within the established EN 3 framework, it has the potential to give manufacturers, distributors, fire-safety professionals and end users greater confidence when comparing products. 

However, scope remains critical. 

The proposed standard focuses on defined small lithium-ion battery risks. It should not be treated as universal approval for every battery, every application or every stage of thermal runaway. 

Until the completed standard is published, all claims should remain precise, evidence-based and specific to the individual product tested. 

Sources: BSI standards-development project | FprEN 3-11 scope summary


Need Help Assessing Your Lithium-Ion Battery Fire Risk?

Firechief® provides specialist solutions to help organisations manage lithium-ion battery risks throughout the battery lifecycle, including extinguishers, fire-resistant storage, containment and battery-disposal products. 

Explore the Firechief® lithium-ion battery safety range. 
 

For advice on selecting the right equipment for your application, speak to the Firechief® team. 


Disclaimer

The information in this article is provided for general informational and educational purposes only. It should not be treated as a substitute for professional fire-safety, technical, legal or regulatory advice. 

Standards, testing requirements and certification arrangements may change as BS EN 3-11 continues through the development and publication process. Readers should check the latest information from BSI, the relevant standards body, the product manufacturer and a competent fire-safety professional before making decisions about equipment selection or compliance. 

The suitability of any fire extinguisher will depend on the specific battery risk, application, product model and supporting test evidence. Always follow the manufacturer’s instructions, site emergency procedures and advice from the relevant Fire and Rescue Service. 

In the event of a lithium-ion battery fire, thermal runaway, significant smoke, unusual heat, swelling or off-gassing, move to a safe location, raise the alarm and call 999. Do not attempt to tackle a fire where it is unsafe to do so. 

Sources: London Fire Brigade emergency guidance | BSI standards-development project


Posted in
CONTENTS